 1. DC-AC POWER INVERTER

Model No.
SA-1500A
SA-4000A
SA-4000B
SA-5000A
SA-5000B
Input Voltage  (V)DC
12
12
24
12
24
Output Voltage (V)AC
220
220
220
220
220
Output Power (Watts)
150
400
400
500
500
Output Frequency (Hz)
50/60
50/60
50/60
50/60
50/60
Efficiency  (%)
90
85
90
90
90
Charging Rate  (AMP)
12
33
16
42
21
Dimension(HxWxL)mm
42x97x132
68x210x200
68x210x200
68x210x200
68x210x200
Weight
600
2240
2240
2240
2240

 

 

 

Model No.
SA-7000A
SA-7000B
SA-10000A
SA-10000B
Input Voltage (V)DC
12
24
12
24
OutputVoltage (V)AC
220

220

220
220
OutputPower (WATTS)
700

700

1000
1000
Output Frequency Hz
50/60

50/60

50/60
50/60
Efficiency  (%)
80
90
75
80
Charging Rate (AMP)
60
30
84
42
Dimension(HxWxLmm)
68x210x230

68x210x230

68x210x355
68x210x355
Weight (g)
2600

2600

4300
4300
 
 2. DC-DC CONVERTER 
       Input Voltage: 24 Volt            Output Voltage: 12 Volt                Output Power: 360 Watt

 

3. Specifications of Solar charger and Controller
 
Function
      Solar charge, Protection of over charge and L.V.D.
      Input voltage of solar : 0 ~30V
      Max. Input Amp. Of solar : 10A(SA-1000A)
      Battery -  Voltage : DC 12V
                     -  Max. charge Voltage : 14.8V
                     -  L.V.D voltage : 10.6V
      Max. load : 30A, 360W
 
Method
       Voltage and pulse method
       Control of reference voltage with F.E.T
 
L.E.D. Level Meter(1 to 10)
       1 : 10.6 Volt
      10 : 13.8 Volt
      Solar LED : Display of Power and Solar charge
      Load LED : Display of Low Battery
 
 3-1 Solar Charger
 Model No.
SC-200
SC-500
SC-1000
SC-2000
SC-3000
SC-4000
Output
0-27V
0-27V
0-27V
0-27V
0-27V
0-27V
Output power 
20W
50W
100W
200W
300W
400W
 
3-2 Solar Charge Controller
* All models have charge output and control of output
Model No.
SCC-200A
SCC-500A
SCC-1000A
SCC-2000A
SCC-3000A
SCC-4000A
Voltage
Charge Output
0-27V
0-27V
0-27V
0-27V
0-27V
0-27V
Controlled Output
10.5V
10.5V
11.0V
11.0V
11.0V
11.0V
Output power
20W
50W
100W
200W
300W
400W
 
4. DC/AC Inverter battery Charger ( un-interrupt potable power supply )
Power Line 153A
Power Line 154A
Power Line 154B
Power Line 253
Power Line 153A
Feature
 
   It will give emergency light to you when you are faced at any light problems
      at any place.
   DC/AC Inverter battery charger with solar panel will be used as main power
      when you are faced at no electric power at any place.
   No Noise
   Free air pollution
   Easy to handle
   Charge from car battery and home
   Long life cycle of battery with special circuit board.          
 
Function
    Auto charging
    Cut off over-charge
    Cut off low battery
    Alarm for low battery
    Extension of extra battery
    Indication lamp : status of charge output & finished charge
    Time of use : Min. 8 hours with a piece of 20W fluorescence lamp

 

 
Power Line 154A
    Lighting for emergency & Leisure and Using home electric
 
Power Line 154 B ( For computer & Note Book )
    Auxiliary UPS kit to constantly supply and charge electric power to Power Line 154A
 
 
Basic specification

Model

Power Line 153A

  Power Line 154A

Power Line 154B

Power Line 253

Output jacks(Plugs)

1 ea

2 ea

-

3 ea

Sealed lead acid battery

1ea x DC12V/12AH

1ea x DC12V/12AH

-

4ea x DC12V/18AH

Output voltage

220V +/- 5%

AC110/220V +/- 5%

-

AC110/220V +/- 5%

Output current(DC)

-

-

DC 12AH

-

Output frequency

50 / 60Hz

50 / 60Hz

-

50 / 60Hz

Inverter output power

40 W

150W RMS

-

250W RMS

Surge output power

-

300W

-

500W

Input voltage

DC12V / 12AH

DC12V / 12AH

-

DC12V / 72AH

AC charger input voltage

220 V

AC110/220V

AC110/220V

AC110/220V

Solar charger input voltage

Max. DC27V / 50W

Max DC27V / 50W

-

Max DC27V / 50W

Efficiency

-

96%

-

94%

Dimension (WxDxH mm)

240 x 105 x 160

250 x 100 x 160

120 x 100 x 160

310 x 200 x 250

Weight

6.65kg

7.2Kg

4.6Kg

40Kg

 
 Functional specification (Power Line 154A & Power Line 253)
 
        Limited output to supply AC power to home appliances during outage.
        Constant output to use home appliances including computer during being charged by AC(Wall outlet) and Solar energy.
        Auxiliary UPS function of Power Line 154B to constantly supply electric power to Power Line 154A only during AC power
          is on with being charged by AC or Solar.
        Surge protection function (like an ordinary UPS) for home appliances and On-going memory Back-up/Internet of computer
           in case of blackouts.
        Audible low battery alarm.
        3-way battery charging by AC(Wall outlet), Solar energy and car battery.
        Charging time of 4~5hours by AC(Wall outlet), 3~4 hours by Solar energy 50W & 3~4hours by car battery.
        Extendible battery capacity (Using time) without limit by connecting with additional batteries.
        Car engine start assistance (Boosting) with 12AH of Power Line 154A and 72AH of Power Line 253.
        Over discharge cut-off circuit.
        Glass fuse protectio
n
 
Applications 
        Camping
        Emergency light
        Emergency power
        Small store on road
        Move light at any place

ESEL TechTra Inc.
 #1382-4, Kuweol-3dong, Namdongku, Incheon,Korea
E-mail: lab@labkorea.com