R-211 Series  Glass Reactor System

General

Features

Magnetic Drive

Agitators

Applications

DC Motor

Stand

Heater Rating

Cover Openings

Flush Bottom Valve

R-211 Series Glass Reactor Specifications

R-211 Series Glass Reactor Control System

Glass Vessel Ordering Information

Accessories

Multi Pilot Plant System (P&ID)

Ordering Information

 
General
 
         - Capacity of this R-211 Series Glass Reactor is from 300ml up to 10 Liters, and designed
            for using in 50~220 psig at 250`C.
         - This R-211 Series Glass Reactor is designed also to have the choice of purchasing only Glass Vessel(R-201)
            for much more economic performances of the system.
         - Glass Vessel can be used in maximum pressure of 220 psig at 250`C
         - Bench and Floor Stand are designed for the most convenient way for working.
         - This R-211 Series Glass Reactor is designed to use the Metal Seal Ring, when higher than 250`C,
           at low torque closure, too, and when lower than 250`C, you can use "O"Ring as well.
         - This R-211 Series Stirred Reactor is designed to be compatible in its capacity;
            you can use 500 ml and or 2000ml Vessel for 1000ml Reactor.
 
 Features
 
         - Capacity : 300ml - 10 Liter
         - Design Pressure : 220psig
         - Design Temperature : -30`C ¡­ 250`C
         - Materials : Glass
         - Power  : 110VAC and 220 VAC, 220 VAC/3-Phase
         - DC Motor : 60W, 90W, 1/8hp, 1/4hp, 1/2hp, 1hp.
         - Magnetic Drive : 16 in-lbs, 32 in-lbs, 64 in-lbs, 120 in-lbs.
         - RPM : 0 ~ 1800 rpm
         - Heater : 0.5KW ~ 5KW
         - Stand : Bench and Floor Stand
         - Gas Inlet Nozzle and Valve
         - Gas Vent Nozzle and Valve
         - Sample Nozzle and Valve
         - Thermowell and "K" Type Thermocouple
         - Cooling Coil Inlet and Outlet Nozzle
         - Pressure Gauge and Pressure Transmitter
         - Relief Valve
 
  
Magnetic Drive
 
         - The pressure and temperature of our M-Series Magnetic Drive is designed to be used for 5,000psig at up to 500¡É
         - You have many choices to use of our Magnetic Drive as the torque varies 8, 16, 32, 64
            and 120 in-lbs according to the different capacity of Reactor.
         - The rpm of our Magnetic Drive is designed for using from 100 up to 3,500 rpm.
         - The Agitator for our Magnetic Drive should be selected based on the viscosity of Reactant.
         - The Material used for building our Magnetic Drive is Samarium Cobalt.
 
Agitators
 
         - Standard Impeller of R-211 Series Reactor is Pitched Blade Turbine which is able to use up to 2,500 rpm.
         - Anchor Impeller is able to use when the viscosity comes up more than 10,000 to 50,000cp.
         - With Helical Impeller, as in the case of High Polymerization, you can use at high viscosity such as more than 50,000 cp.
         - Propeller Impeller is used for the same application as of Pitched Blade Turbine.
 

Pitched Blade Turbine

Anchor Impeller

Helical Impeller

 
Applications
 
         - Applications of our R-211 Series Reactor are for;
             - Polymerization                    
             - Organic Synthesis
             - Hydrogenation
             - Dehydrogenation
             - Catalytic Reaction
             - Oxidation
             - Isomerization
             - Amination
             
DC Motor
 
         - 60W Motor to be used for 300ml R-211 Series Reactor and 90W Motor to be used for 500ml Reactor.
         - 1/8hp and 1/4hp Motor to be used for 1 Liter ~ 2 Liter Reactor.
         - 1/2hp and 1hp Motor to be used for 4 Liter ~ 10 Liter Reactor.
 
Stand
         - Either Bench Stand or Floor Stand will be used for R-211 Series Reactor.
 
Heater Rating
 
         - 0.5KW ~ 0.8KW Band Heater to be used for 300ml Reactor
         - 0.8KW ~ 1KW Band Heater to be used for 500ml ~ 1Liter Reactor.
         - 1.2KW ~ 1.5KW Band Heater to be used for 2Liter ~ 4Liter Reactor.
         - 4KW ~ 5KW Band Heater to be used for 8LIter ~ 10Liter Reactor.
         - Options : Reactor Vessel Jacket Type design also available for option.
                            Oil Circulator is also available for option.
 
Cover Openings
 
         - Two for Cooling Coil : 1/8" NPT and 1/4"NPT(F)
         - Gas Inlet Nozzle and Valve : 1/8" ~ 1/4" NPT(F)
         - Gas Vent Nozzle and Valve : 1/8" ~ 1/4" NPT(F)
         - Sample Valve and Tube : 1/8" ~ 1/4"NPT(F)
         - Pressure Gauge and Relief Valve : 1/8" ~ 1/4" NPT
         - Magnetic Drive : M-24-1.5P
         - Solid Charging Nozzle : 1/4"NPT
 
Flush Bottom Valve
 
         - Design Pressure : 1,000psig ~ 5,000psig
         - Design Temperature : 100`C ~ 400`C
         - Materials : 316SS, Hastelloy.C-276, Titanium
         - Size : 1/4"NPT, 1/2"NPT, 1"NPT, 2"NPT
 
R-211 Series Glass Reactor Specifications
 

Series

Volume

I.D.

I.L.

Conn. Size

Stand

Std. Heateer Voltage

Heater, KW

211-3

300ml

51mm

150mm

1/8" NPT

Bench

220/1/60

0.5

211-5

500ml

55mm

230mm

1/8" NPT

Bench

220/1/60

0.8

211-1

1000ml

86mm

180mm

1/4" NPT

Bench

220/1/60

1.0

211-2

2000ml

94mm

280mm

1/4" NPT

Bench

220/1/60

1.5

211-4

4000ml

127mm

330mm

3/8" NPT

Floor

220/1/60

2.0

211-8

8000ml

155mm

460mm

3/8" NPT

Floor

220/1/60

3.5

211-10

10000ml

203mm

584mm

3/8" NPT

Floor

220/1/60

5.0

 

Series

Max. Pressure

Mag. Drive

Motor

Jacket Design

Pressure Utility Connections

211-3

220 psig

16 in-lbs

1/12hp

30psig

Gas Inlet & Valve, Vent Valve
Sample Tube & Valve, Process(MD)
Cooling Inlet & Outlet
Thermowell, Drain
Spare Nozzle
Mag. Drive  Water Inlet & Outlet

211-5

220 psig

16 in-lbs

1/8hp

30psig

211-1

220 psig

16 in-lbs

1/4hp

30psig

211-2

150 psig

16 in-lbs

1/4hp

30psig

211-4

150 psig

32 in-lbs

1/2hp

30psig

211-8

100 psig

60 in-lbs

1/2hp

30psig

211-10

100 psig

60 in-lbs

3/4hp

30psig

 
 
R-211 Series Glass Reactor Control System
 
         1. Manual Control
             This R-211 Series Reactor is designed for T-211, S-211 and P-211 to be used conveniently in the Control Box.
             Also is designed for the Cable between Reactor Control box to be separated easily by using quick-connect couplings.
 
           1) Temperature Control (T-211)
               - Size : 96mm ¡¿ 96mm
               - Calibration : Accuracy ¡¾0.15% of reading
               - Process : TC Inlet Type "K"  (Chromel - Alumel) Standard
               - Process : TC Range : 0 ~ 1200¡É for Type "K" TC
               - Indication : 16 Segment Green LFD, Digital-4 digits
               - Cycle Time : 3 to 80 Seconds
               - TC Break : Upscale Shutdown
               - Output : 4~20mA & SCR
               - Power : 220VAC, 60Hz, 1Phase
 
           2) Speed Control (S-211)
               - Power : 220VAC, 60Hz, 1Phase
               - Indicator Accuracy : ¡¾1 Count
               - Indicator : 4 digits
               - Resolution : 1 rpm
               - Motor Contrl Speed Range : 50 : 1
               - Max. Motor Size: 3/4 hp            
               - Motor Voltage : 0~180VDC  (220VAC Input)
               - Output : 0~12VDC
               - Size : 48mm¡¿96mm
 
           3) Pressure Control (P-211)
               - Transducer Excitation : 10VDC
               - Type of Input Accepted : 1~5mV/L
               - Transducer Current Drive : 120mA
               - Transducer Impedance : 120 §Ù
               - Analog Output : 5V, 10V, ¡¾10V, 4~20mA
               - Temperature Drift : 0.02% F-S/`C
               - Display Size : 16mm Large
               - Resolution Maximum : ¡¾19999
               - Weight : 500g
               - Size : 48mm ¡¿ 96mm
               - Power : 220VAC, 60Hz, 1Phase
 
         2. Computer Control
        
Glass Vessel Ordering Information
  

Order No.

Capacity

Pressrue

Dimensions(mm)

 

A

B

C

D

E

211-G3

300ml

220psig

111

220

71

51

150

211-G5

500ml

220psig

115

300

75

55

230

211-G1

1000ml

220psig

146

250

108

86

180

211-G2

2000ml

150psig

154

350

118

94

280

211-G4

4000ml

100psig

187

400

155

127

330

211-G8

8000ml

50psig

215

530

185

155

460

211-G10

10000ml

50psig

263

654

233

203

584

 
 
Accessories
 
You can expand the versatility of any 211 series reactor further, through the additions of options and accessories :
            - Catalyst Baskets
            - Baffles
            - Glass Liners & Teflon Liners
            - R-201 Pressure Vessel
            - Flush Valve
            - Torque Meters
            - Flexible Hose
            - Reflux Condensers
            - Sight and Light Windows
            - Feed Tanks
            - Solid Charging System
            - Heat Transfer Package
 
Multi Pilot Plant System(P&ID)
 
Ordering Information
 

211

A

B

C

D

E

F

G

H

I

 

Capacity

Pressure

Temp.

Material

Agitator

Power

Drive

Magnetic Drive

Controller

Series

211

 

 

 

 

1: 300ml

2: 500ml

3: 1 L

4: 2 L

5: 4 L

6: 8 L

7: 10 L

8: Other

1 : 50psig

2 : 100psig

3 : 150psig

4 : 200psig

5 : 220psig

6 : Other

1 : 100 `C

2 : 150 `C

3 : 200 `C

4 : 250 `C

5 : Other

1 : 304SS

2 : 316SS

3 : Hast.C

4 : Titanium

5 : Glass

6 : Hast.B

7 : Other

1 : Turbine

2 : PBT

3 : Propller

4 : Helical

5 : Anchor

6 : Other

1 : 110/60/1

2 : 220/60/1

3 : 210/60/3

4 : Other 

1 : Air M.

2 : AC M.

3 : DC M.

4 : Other 

1 : MD

2 : MS

3 : Other

1 : PID/Tach/PG

2 : PID/Tach/PI

3 : R & S/Tach/PIC

4 : PLC(LabVIEW Software)

5 : ConBoy Software

6 : Other

 Send your inquiryInquiry form
 E-mail: lab@labkorea.com
ESEL TechTra Inc.
 #1382-4, Kuweol-3dong, Namdongku, Incheon, korea
 ¨ÏCopyright 1999 www.labkorea.com ® All right reserved