Large steam sterilizer
   HS-700S, HS-1000S, HS-1000D
Middle steam sterilizer
   
HS-4085S, HS-5020S, HS-5025S/D
   HS-5035S/D, HS-250, HS-350S
Semi-automatic steam sterilizer
   HS-85, HS-196
Vacuumclave steam sterilizer
   HS-2321V, HS-3041V
Autoclave
  - Gravity type steam sterilizer
    HS-1212, HS-1321, HS-9041
  -  Vertical type steam sterilizer
    HS-60
Field hospital steam sterilizer
   HS-1636
EO gas sterilizer
   | HS-4085EO | | HS-700EO |
Ultraviolet rays sterilizer
   H-3000B, H-5000A, H-8000C

Semi-automatic steam sterilizer

| Specification |

 

HS-85

HS-196

| Feature |

It has the built-in cycle program to process the wrapped instruments or textile products and unwrapped instruments as well as the liquids; the phases of <READY>,<STERILIZATION>,<SLOW or FAST EXHAUST>,<DRYING> and <COMPLETION> are automatically performed.

 1. The Temperature Controller/Recorder precisely controls the set temperature for sterilization and at the same time, the sterilization temperature is recorded in graph on the chart for 24 hours whereby the result of sterilization can be checked; it can also serve as the thermometer indicating the present temperature.

2. It is equipped with the vacuum system consisting of powerful water pump and ejector, therefore it performs the air removal as the prevacuum and performs drying phase as the post vacuum after sterilization phase. consequently, it effective in improving the penetration of sterilization agent and the drying performance, and shortening the cycle time and reducing the noise and the trouble rate of equipment.

 

3. If the door is not locked, the cycle is not started; if the pressure of 0.3§¸f/§² or more remains in the chamber after sterilization,

the safety device prevents the door from being opened.

 

4. The standard type HS-250 uses the built-in steam generator exclusively for the steam source while the standard type HS-350s can

use exclusively the external steam. But either the built -in steam generator or the external supply system can be exclusively used;

otherwise both of them can be concurrently used regardless model type upon the request of the user.

 

5. The built-in steam generator is equipped with electric heater,automatic temperature regulator, automatic water feed

system and safety valves, etc.; it is the device which ensures a stable supply of saturated steam whereby the sterilizer (HS-250)

can be used without the limitation of location.

 | Specification |

MODEL

HS-85

HS-196

Cabinet

Stainless Steel Plate

Stainless Steel Plate

W600×H1,100×D790mm

W700×H1,600×D1,120mm

Chamber

Cylindrical w/Jacker (SUS316)

Cylindrical w/Jacker (SUS316)

Ø400×L680mm,85.4§¤cap.

Ø500×L1,000mm,196§¤cap.

Air Removal

Gravity

Gravity

Operating
Temperature

121¡É(1.0§¸f/§²)¡­132¡É(2.0§¸f/§²)

121¡É(1.0§¸f/§²)¡­132¡É(2.0§¸f/§²)

Power Source

AC220V,1ph,50/60§Ô,22A or

AC220V,1ph,50/60§Ô,454A or

AC220V,3ph,50/60§Ô,13A or

AC220V,3ph,50/60§Ô,25A or

AC380V,3ph,4wire,50/60§Ô,8A

AC380V,3ph,4wire,50/60§Ô,15A

Steam Source

Standard : Built-in Steam Generator

Standard : Built-in Steam Generator

0.45bhp, max. 2.5§¸f/§²

0.9bhp, max. 2.5§¸f/§²

Heater : 405§Ò

Heater : 9§Ò

Optional: External Steam System

Optional: External Steam System

Saturated Steam of min. 97% Dryness

Saturated Steam of min. 97% Dryness

Pressure: 3.5§¸f/§²¡­5§¸f/§²

Pressure: 3.5§¸f/§²¡­5§¸f/§²

Flow Rate: max.10§¸/hr

Flow Rate: max.20§¸/hr

Control System

Automatic Pressure Control System

Automatic Pressure Control System

Timer

Electric Powered, 0¡­60min

Electric Powered, 0¡­60min

Loading System

Shelves : W300×L360mm,2ea

Shelves : W450×L450mm,2ea

W238×L626mm,1ea

W275×L954mm,1ea

Rack : 1ea

Rack : 1ea

Net Weight

163kg

255kg

Operational
Environment
Conditions
(IEC 601-1)

¨ÍAn ambient temperature range of +10¡É to +40¡É.
¨ÎA relative humidity range of 30% to 75%.
¨ÏAn atmospheric pressure range of 700hPa to 1,060hPa.
¨ÐA temperature of the water at the inlet of water-cooled EQUIPMENT not higher than 25¡É.