Vacuumclave steam sterilizer

| Specification |

 

HS-2321V

HS-2321V

| Feature |

Until recently air removal of chamber and drying based on the employ of the vacuum system has been used exclusively for the large steam sterilizer. Our company has adopted the vacuum system for the tabletop sterilizer despite the various restrictions, thereby satisfying the requirements of the standards (MDD) of EU. This is very meaningful in that air removal based on the prevacuum system is adopted in sterilizing the wrapped items and the drying based on the post vacuum system is also very important in the sense that the drying of sterilized items are as important as sterilization.

1. It has five(5) kinds of sterilization cycle and two(2) kinds of test cycle programs; the sterilization time and drying time can be shortened with the result that good sterilization can be obtained depending on the features of the vacuum system. Especially, it has the built-in cycle exclusively employed for the liquids which can solve problems caused when sterilizing the culture medium or the liquids with a small sterilizer for the clinical examination.

 

2.The cycle is fully automated by the Control System with the micro processor and its self-diagnosis function can detect six(6) kinds

of abnormality and suspend the cycle.

3. It is mounted with the printer which prints out important reference data(date, temperature, pressure, time, errors, etc.) to be analyzed,

examined and kept regarding the result of sterilization.

|specification |

MODEL

HS-2321V

HS-3041V

Overall

W516×H402×D702mm

W614×H484×D792mm

Cabinet

W516×H360×D586mm

W614×H442×D646mm

Chamber

W225×H225×D425mm,
Capacity : 21.5§¤(SUS316)

W300×H300×D450mm,
Capacity : 40.5§¤(SUS316)

Reservoir

W230×H175×D125mm,
Capacity : 3§¤

W230×H175×D125mm,
Capacity : 3§¤

Tray

W216×H44×D405mm, Qty : 2ea

W291×H44×D432mm, Qty : 2ea

Operating Temperature

121¡É¡­132¡É

121¡É¡­132¡É

Sterilization Agent

Saturated Steam of 1¡­2.1bar Pressure

Saturated Steam of 1¡­2.1bar Pressure

Air Removal

Vacuum / Gravity

Vacuum / Gravity

Vacuum Pump

Flow Rate: 5§¤/min

Flow Rate: 11§¤/min

Power source

AC230v, 50/60§Ô

AC230v, 50/60§Ô

Power Consumption

1,600W

2,000W

Control

Microprocessor

Microprocessor

Display

160×128 Dots Graphic Display,
LCD(EL back - light)

160×128 Dots Graphic Display,
LCD(EL back - light)

Printer

Dot Matrix, 40 Columns, Single Color

Dot Matrix, 40 Columns, Single Color

Net Weight

64kg

91kg

Operational
Environment
Conditions
(IEC601-1)

¨ÍAn ambient temperature range of +10¡É to +40¡É.
¨ÎA relative humidity range of 30% to 75%.
¨ÏAn atmospheric pressure range of 700hPa to 1,060hPa.
¨ÐA temperature of the water at the inlet of water-cooled EQUIPMENT not higher than 25¡É.