UNIVERSAL
TESTING MACHINE
Universal Testing Machine > EMC SERIES> Accessories
ACCESSORIES
MECHANICAL WEDGE GRIPS > GK - SERIES
|
Grips Gk are intended for loading testing specimens by tension. Grip Gk enables quick fixing of flat and cylindrical specimens. For fixing specimens of different types and diameters there are easily exchangeable jaws at disposal. Fixing specimens of other types and shapes is possible with the help of adapters. Adapters for connecting of button and thread end specimens of other types and shapes is possible with the help of adapters. Adapters for connecting of button and thread end specimens are delivered. For fixing textile specimens it is possible to use jaws with profile. |
Technical Parameters
TYPE |
GK 5 |
GK10 |
GK 20 |
GK 50 |
GK 100 |
GK 200 |
GK 300 |
|
Nominal load |
kN |
5 |
10 |
20 |
50 |
100 |
200 |
300 |
Range of thickness of flat specimens |
mm |
0-15 |
0-15 |
0-16 |
0-16 |
0-16 |
0-16 |
0-16 |
©ªrange of cylindrical specimens |
mm |
8-16 |
8-16 |
8-16 |
8-16 |
8-20 |
8-20 |
8-20 |
|
Press plates are intended for pressure loading of testing specimens. Lower plate is fixed, upper one is set swing. Surface of the plates is hardened and provided with concentric rings for easy centering of specimens.
|
Technical Parameters
TYPE |
|
CP 5 |
CP10 |
CP20 |
CP50 |
CP100 |
CP200 |
CP 300 |
Nominal load of plate |
kN |
5 |
10 |
20 |
50 |
100 |
200 |
300 |
mm |
100 |
100 |
100 |
140 |
160 |
200 |
200 |
THREE/FOUR BENDING JIG > BD - SERIES
|
Equipment BD is intended for bend test. It enables easy setting up the distance of rollers on basic body. Rollers are exchangeable for rollers of other diameters. The press plate CP can be mounted to the equipment BD. |
Technical Parameters
TYPE |
|
BD-5 |
BD-10 |
BD-20 |
BD-50 |
BD-100 |
BD-200 |
BD-300 |
Nominal load |
kN |
5 |
10 |
20 |
50 |
100 |
200 |
300 |
low span |
mm |
120 |
120 |
120 |
180 |
250 |
300 |
360 |
roller dia x length |
x mm |
10 x 50 |
50x50 |
50x50 |
50x120 |
50x120 |
50x120 |
50x120 |
AXIAL EXTENSOMETER (Option) > PXA - SERIES
|
Axial extensometers are intended for measuring extension and shortening particularly metal flat and round specimens. Extensometers are mounted on the specimen with the help of small springs or quick fixtures. Extensometers are characterized by high accuracy and small activation force needed to moving arms during extension or shortening the specimen. Axial extensometers have high own frequency and are suitable for measuring extension during dynamic loading of testing specimen up to the frequency approximately 120 §Ô. Axial extensometers have easily exchangeable arms. |
Technical Parameters
TYPE |
|
100 |
101 |
102 |
103 |
104 |
Gauge length |
mm |
20 |
25 |
25 |
50 |
50 |
Travel |
% |
+20 |
+20 |
-10 ~ +50 |
+20 |
+50 |
Non Linearity |
% |
0.15 |
||||
Activation force |
N |
0.6 |
0.6 |
0.25 |
0.6 |
0.25 |
Weight without cable |
g |
15 |
15 |
20 |
19 |
29 |
Working temp. |
`C |
-20 ~ + 120 |
||||
Principle |
|
Tensometric |
||||
Sensibility |
mv / V |
1.3 |
||||